Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Dental press j. orthod. (Impr.) ; 28(5): e2323183, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520822

RESUMO

ABSTRACT Introduction: Artificial Intelligence (AI) is a tool that is already part of our reality, and this is an opportunity to understand how it can be useful in interacting with patients and providing valuable information about orthodontics. Objective: This study evaluated the accuracy of ChatGPT in providing accurate and quality information to answer questions on Clear aligners, Temporary anchorage devices and Digital imaging in orthodontics. Methods: forty-five questions and answers were generated by the ChatGPT 4.0, and analyzed separately by five orthodontists. The evaluators independently rated the quality of information provided on a Likert scale, in which higher scores indicated greater quality of information (1 = very poor; 2 = poor; 3 = acceptable; 4 = good; 5 = very good). The Kruskal-Wallis H test (p< 0.05) and post-hoc pairwise comparisons with the Bonferroni correction were performed. Results: From the 225 evaluations of the five different evaluators, 11 (4.9%) were considered as very poor, 4 (1.8%) as poor, and 15 (6.7%) as acceptable. The majority were considered as good [34 (15,1%)] and very good [161 (71.6%)]. Regarding evaluators' scores, a slight agreement was perceived, with Fleiss's Kappa equal to 0.004. Conclusions: ChatGPT has proven effective in providing quality answers related to clear aligners, temporary anchorage devices, and digital imaging within the context of interest of orthodontics.


RESUMO Introdução: A Inteligência Artificial (IA) é uma ferramenta que já faz parte de nossa realidade, e esta é uma oportunidade de entendermos como ela pode ser útil na interação com os pacientes e no fornecimento de informações valiosas sobre Ortodontia. Objetivo: O objetivo deste estudo foi avaliar a precisão do ChatGPT em responder a perguntas sobre Alinhadores transparentes, Dispositivos de ancoragem temporária, e Imagens digitais em Ortodontia. Métodos: 45 perguntas e respostas foram geradas pelo ChatGPT 4.0 e analisadas separadamente por cinco ortodontistas que, de forma independente, avaliaram a qualidade das informações fornecidas, usando uma escala de Likert, na qual pontuações mais altas indicavam uma maior qualidade das informações (1 = muito ruim; 2 = ruim; 3 = aceitável; 4 = bom; 5 = muito bom). Aplicou-se o teste H de Kruskal-Wallis (p < 0,05) e comparações pareadas post-hoc com correção de Bonferroni. Resultados: Das 225 avaliações dos cinco avaliadores diferentes, 11 (4,9%) foram consideradas como muito ruins, 4 (1,8%) como ruins, e 15 (6,7%) como aceitáveis. A maioria foi considerada boa [34 (15,1%)] ou muito boa [161 (71,6%)]. Com relação às pontuações dos avaliadores, percebeu-se uma leve concordância, com o Kappa de Fleiss igual a 0,004. Conclusões: O ChatGPT mostrou eficácia em fornecer respostas de qualidade para questões relacionadas a Alinhadores transparentes, Dispositivos de ancoragem temporária e Imagens digitais.

2.
Arq. bras. oftalmol ; 83(2): 127-131, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088964

RESUMO

ABSTRACT Purpose: Inferior eyelid laxity is classically evaluated using "snap-back" and "distraction" tests. This study aimed to assess the reproducibility of the technique used to indirectly quantify the horizontal tension in the lower eyelids using digital image processing. Methods: This longitudinal study was conducted to assess the reproducibility of a new technique that quantifies the horizontal tension in the lower eyelid. The study was conducted at the Hospital das Clínicas of Porto Alegre. The protocol was established by two trained ophthalmologist examiners, allowing intra- and interobserver agreement analyses. Image acquisition was done in two stages: the first image was captured with the eyelid in primary gaze position and the second with the eyelid in traction position. All images and measurements were processed using Image J 1.33m software from the National Institute of Health. The Bland-Altman method, intraclass correlation coefficients, concordance correlation coefficients, and technical measurement error were used to evaluate reproducibility. Results: The study participants comprised healthy individuals with no ophthalmologic pathologies. The measurements obtained in the neutral position showed a slightly higher agreement than those obtained in the traction position. The mean difference between the measurements performed in the traction position was 0.028 ± 0.7 mm and 0.014 ± 0.9 mm in the intra- and interobserver analyses, respectively. The Bland-Altman method demonstrated adequate confidence limits for both measurements. Correlation coefficients for measurements varied between 0.87 [95% confidence interval (CI) 0.68-0.95] and 0.91 (95% CI 0.77-0.97) in the neutral position and between 0.72 (95% CI 0.37-0.89) and 0.76 (95% CI 0.4-0.91) in the traction position. Conclusion: A high intra- and interobserver concordance was observed in the studied method to quantify lower eyelid tension. The proposed method is simple and easily reproducible, and to the best our knowledge, this is the first method that quantifies lower eyelid horizontal tension on the basis of digital image processing. This modified distraction test might be useful in studies quantifying lower eyelid horizontal tension.


RESUMO Objetivo: A frouxidão palpebral inferior é avaliada classicamente por meio de testes de "snap-back" e "distraction test". O objetivo deste estudo foi avaliar a reprodutibilidade da técnica utilizada para quantificar indiretamente a tensão horizontal nas pálpebras inferiores através do processamento digital de imagens. Métodos: Este estudo longitudinal foi realizado para avaliar a reprodutibilidade de uma nova técnica que quantifica a tensão horizontal na pálpebra inferior. O estudo foi realizado no Hospital das Clínicas de Porto Alegre. O protocolo foi estabelecido por dois examinadores oftalmologistas treinados, permitindo análises de concordância intra e interavaliador. A aquisição de imagens foi feita em duas etapas: a primeira imagem foi capturada com a pálpebra na posição primária do olhar e a segunda com pálpebra tracionada. Todas as imagens e medições foram processadas usando o software Image J 1.33m do National Institute of Health. O método de Bland-Altman, os coeficientes de correlação intraclasses, os coeficientes de correlação de concordância e o erro técnico da medida foram utilizados para avaliar a reprodutibilidade. Resultados: Os participantes do estudo foram indivíduos saudáveis e sem patologias oftalmológicas. As medidas obtidas na posição neutra mostraram concordância levemente maior do que as obtidas na posição tracionada. A diferença média entre as medidas realizadas na posição tracionada foi de 0,028 ± 0,7mm e 0,014 ± 0,9mm nas análises intra e interobservadores, respectivamente. O método de Bland-Altman demonstrou limites de confiança adequados para ambas as medidas. Os coeficientes de correlação para as medidas variaram entre 0,87 [intervalo de confiança de 95% (IC) 0,68-0,95) e 0,91 (IC 95% 0,77-0,97) na posição neutra e entre 0,72 (IC 95% 0,37-0,89) e 0,76 (IC 95% 0,46-0,91) na posição tracionada. Conclusão: Observou-se elevada concordância intra e interobservador no método estudado para quantificar a tensão palpebral inferior. O método proposto é simples e facilmente reproduzível, e, do melhor modo possível, este é o primeiro método que quantifica a tensão horizontal da pálpebra inferior com base no processamento digital de imagens. Este teste de distração modificado pode ser útil em estudos que quantifiquem a tensão horizontal da pálpebra inferior.


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Interpretação de Imagem Assistida por Computador/métodos , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/diagnóstico por imagem , Valores de Referência , Software , Fotografação/métodos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Pálpebras/fisiopatologia , Pálpebras/diagnóstico por imagem
3.
São José dos Campos; s.n; 2020. 83 p. il., graf., tab..
Tese em Português | BBO - Odontologia, LILACS | ID: biblio-1248193

RESUMO

O objetivo do estudo foi avaliar o comportamento mecânico de materiais restauradores utilizados na reabilitação da guia canino. O estudo foi dividido em uma etapa in sílico e outra in vitro. Dez modelos 3D de dentes caninos hígidos foram obtidos por engenharia reversa e utilizados como Grupo Controle (n = 10) para o teste in sílico por meio da análise por elementos finitos (FEA). Um desgaste incisal de 2 mm foi simulado em cada amostra 3D e reabilitado com restauração incisal direta de resina composta (Grupo IRC, n = 10) e indireta de cerâmica (Grupo IC, n = 10). Os mesmos modelos também receberam, além do desgaste incisal, um preparo vestibular para faceta laminada, restaurados com os mesmos materiais, compondo os Grupos FRC (faceta de resina composta, n = 10) e FC (faceta cerâmica, n = 10). Os modelos foram exportados para um software de engenharia assistida por computador (CAE) e as geometrias foram transformadas em malhas de elementos tetraédricos, consideradas sólidas, isotrópicas, homogêneas e lineares. Uma carga de 100 N foi aplicada simulando a desoclusão pelo canino para análise mecânica estrutural dinâmica. A deformação total foi mensurada e a tensão máxima principal foi usada como critério de falha. Com base nos resultados da avaliação in sílico, dois tipos de restauração foram selecionados para a fase in vitro, onde realizou-se um ensaio mecânico de fadiga para análise do desgaste. Trinta dentes caninos hígidos foram distribuídos em três grupos: Controle (n = 10), IRC (n = 10) e FC (n = 10). As amostras foram submetidas ao ensaio de fadiga em cicladora mecânica com deslizamento de 2 mm por 240.000 ciclos, carga de 49 N e 4 Hz de frequência, imersas em água em temperatura ambiente. A cada 60.000 ciclos as amostras foram moldadas e seus modelos escaneados para avaliação da quantidade de desgaste através da técnica de correlação por imagem digital, quantificando a perda de estrutura a cada intervalo. As técnicas restauradoras com resina composta sofreram maior deformação total, tendo a cerâmica um comportamento semelhante ao dente hígido. A probabilidade de falha no movimento de desoclusão foi menor na cerâmica. Para o desgaste, não houve diferença significante entre grupos experimentais até 180.000 ciclos. Aos 240.000 ciclos, a resina composta apresentou maior desgaste que a cerâmica (p = 0,02). Todos os grupos provocaram desgaste em seus antagonistas, mas não houve diferença significante entre eles (p < 0,05). Dentro das limitações deste estudo, pode-se concluir que os laminados cerâmicos apresentaram menor desgaste, deformação e probabilidade de falha na restauração da guia canino. Ainda, a anatomia do dente e o tipo de restauração influenciaram o comportamento dos materiais(AU)


The purpose of this study was to evaluate the mechanical behavior of materials restorative used in rehabilitation of canine guide. The study was divided in two parts in silico and in vitro test. Ten 3D models of sound canine teeth were obtained by reverse engineering technique and used as Control Group (n = 10) to in silico test by finite elements analysis (FEA). A 2 mm wear were simulated in each 3D sample and restored according to restorative material; Group IRC (Incisal Composite Resin, n=10) and Group IC (Incisal Ceramic, n = 10). Laminate preparations were modeled and restored with the same materials, Group FRC (Laminate Composite Resin, n=10) and Group FC (Laminate Ceramic, n = 10). All models were exported to Computer Aided Engineering (CAE) software, the geometries were meshed with tetrahydric elements and all contacts were considered perfectly bonded. The load simulated the canine guide (100 N) and the assembly was constrained at the bottom surface to run a structural mechanic dynamic analysis. The Total Deformation was measured and Maximum Principal Stress was used as failure criteria. Thirty sound canine tooth were divided in three groups to in vitro test; Control (n = 10), IRC (n = 10) and FC (n = 10). The samples were subjected to the fatigue test in a wear machine for 240.000 cycles, load of 49 N, frequency of 4 Hz, sliding distance of 2 mm in water at room temperature. The samples were molded every 60.000 cycles and their models scanned to evaluate wear by digital image correlation. Composite resin groups showed higher total deformation and ceramic groups had a more similar behavior to the control group. The probability of failure was lower for the ceramic in the canine guidance. For wear, there was no significant difference between groups up to 180.000 cycles. After 240.000 cycles, the wear was greater in the IRC group (p = 0,02). The wear of the antagonists was not statistically different between groups. Within the limitations of this study, it can be concluded that the ceramic laminates showed less wear, deformation and probability of failure in restoring of the canine guide. In addition, anatomy of the tooth and type of restoration influenced the behavior of the materials(AU)


Assuntos
Desgaste dos Dentes/complicações , Desgaste de Restauração Dentária/efeitos adversos , Análise de Elementos Finitos/estatística & dados numéricos , Restauração Dentária Permanente/métodos
4.
RGO (Porto Alegre) ; 64(4): 484-489, Oct.-Dec. 2016. graf
Artigo em Inglês | LILACS | ID: biblio-842352

RESUMO

ABSTRACT Periapical X-rays are the most common complementary tests in the dental clinic. The indication of image tests in forensic identification depends on the produced X-rays quality. The image processing of conventional radiographs can improve image quality. This study aimed to report the potential contribution of image processing from radiographic films by digitally edited periapical radiographs for case reporting of positive identification. The results of anthropological examinations and dental arches of the victim matched the information transferred by the family of the missing person. The antemortem and postmortem periapical radiographs were digitized on photo scanner (Hewlett-Packard Development Company, HP ScanJet G4050 Photo, United States) and images were processed in Corel PaintShop Pro X4 editing software (Corel Corporation, v14, Canada). The comparison of antemortem and postmortem periapical radiographs digital images allowed to determine 8 concordant points in the contour and delimit the maxillary sinus as well as periodontal and dental structures of the tooth 17. Identification of the individual was possible by digital editing of radiographs in computer software. Editing allowed adjusting image brightness, contrast and sharpness, color temperature and saturation of tooth-jaw structures. Such technological feature effectively contributed to positive identification performed by Forensic Dentistry.


RESUMO As radiografias periapicais são os exames complementares mais frequentes na clínica odontológica. A indicação de exames de imagens na identificação forense depende da qualidade das radiografias produzidas. A edição digital de radiografias convencionais pode melhorar a qualidade de imagem. O presente trabalho consiste em relatar a potencial contribuição do processamento digital de filmes radiográficos através de relato de caso de identificação positiva por radiografias periapicais editadas digitalmente. Os resultados dos exames antropológicos e dos arcos dentários da vítima correspondiam às informações cedidas pelos familiares sobre a pessoa desaparecida. As radiografias periapicais antemortem e postmortem foram digitalizadas em scanner fotográfico (HP Development Company, HP ScanJet G4050 Photo, Estados Unidos) e as imagens processadas no programa de edição Corel PaintShop Pro X4 (Corel(r) Corporation, v14, Canadá). A comparação das imagens digitais das radiografias periapicais antemortem e postmortem permitiu determinar 8 pontos concordantes no contorno e delimitação do seio maxilar e das estruturas dentária e periodontal do elemento 17. A identificação do indivíduo foi possível mediante a edição digital das radiografias em programa de computador. A edição da permitiu ajustar imagens de brilho, contraste e nitidez e cores de temperatura e saturação das imagens das estruturas dento-maxilares. Esse recurso tecnológico contribuiu de forma efetiva para a identificação positiva realizada pela Odontologia Legal.

5.
Ciênc. rural ; 46(6): 984-990, June 2016. tab
Artigo em Inglês | LILACS | ID: lil-779821

RESUMO

ABSTRACT: Nitrogen (N) is the main nutrient responsible for the green coloration of lawns but also stimulates the growth of the aerial portion of grass, thus increasing mowing expenses. Therefore, herbicides may be used as a growth regulator. The ideal herbicide will reduce lawn height without affecting esthetics. Toward this end, the aim of the present study was to evaluate the green coloration of Emerald grass ( Zoysia japonica Steud.) under the effect of different N doses or herbicides used as growth regulators. The study site consisted of randomized blocks containing 20 treatments arranged in a 5×4 factorial design with four treatment groups: four herbicides (glyphosate, imazaquin, imazethapyr, and metsulfuron-methyl, accounting for 200, 420, 80, and 140g ha-1 of the active ingredient, respectively) and the control sample (no herbicide); and three doses of N in the form of urea (5, 10, and 20g m-2), divided into five applications per year, in addition to a treatment without N. Leaf chlorophyll content (LCC) was assessed and the aerial portion of the lawn was measured with digital image analysis. Doses of N ranging from 10 to 20g m-2, divided into five applications a year, provided the lawn with intense green coloration, and the herbicides glyphosate (200g ha-1), imazaquin (420g ha-1), and imazethapyr (80g ha-1) were reported to be suitable for use as growth regulators of the study species, considering maintenance of esthetic quality (green coloration). The digital image analysis of the aerial portion provided more accurate results than use of a chlorophyll meter with regard to the recommendation of both N dose and herbicides to be used as growth regulators of Emerald grass.


RESUMO: Embora o nitrogênio (N) seja o principal nutriente responsável pela coloração verde dos gramados, o mesmo estimula o crescimento da parte aérea, resultando em maior dispêndio com cortes. Assim, a utilização de herbicidas como reguladores de crescimento seria alternativa, sendo ideal aquele que reduzisse a altura sem afetar a estética do gramado. Diante do exposto, objetivou-se avaliar a coloração verde da grama esmeralda ( Zoysia japonica Steud.) sob o efeito de doses de N e do uso de herbicidas como reguladores de crescimento. Utilizou-se o delineamento em blocos casualizados com 20 tratamentos dispostos num fatorial 5x4 com quatro repetições, sendo quatro herbicidas: glyphosate, imazaquin, imazethapyr e metsulfuron-methyl (200, 420, 80 e 140g ha-1 do ingrediente ativo (i.a.), respectivamente) e a testemunha (sem herbicida); e três doses de N na forma de ureia: 5, 10 e 20g m-2, parceladas em cinco aplicações ao ano, além do tratamento sem N. Avaliaram-se o índice de clorofila foliar (ICF) e a análise por imagem digital da parte aérea do gramado. Doses de 10 a 20g m-2 de N, parceladas em cinco vezes ao ano, propiciaram coloração verde intensa do gramado e os herbicidas glyphosate (200g ha-1), imazaquin (420g ha-1) e imazethapyr (80g ha-1) foram adequados para utilização como reguladores do crescimento da espécie estudada, considerando a qualidade estética (cor verde). A análise por imagem digital da parte aérea forneceu resultados mais precisos que o uso do clorofilômetro, quanto à recomendação da dose de N, bem como dos herbicidas a serem utilizados como reguladores de crescimento da grama esmeralda.

6.
Rev. ABENO ; 16(3): 19-27, 2016. tab
Artigo em Inglês | BBO - Odontologia | ID: biblio-881827

RESUMO

The purpose of this study is to introduce a visualization and interaction tool of Augmented Reality in mobile devices using three-dimensional (3D) volumetric images from patients' real tomographic acquisition, and to describe the steps for preparing the models for such 3D visualizations. Augmented Reality was built correlating tomographic images and open-source software, in a sequence of (1) image acquired, that consists of multi-planar images that can be visualized as 3D renderings and are the basis for constructing polygonal surfaces of specific anatomic structures of interest, (2) creation of volumetric models, in which 3D volumetric model can be saved and exported as a 3D polygonal mesh in .stl file format, (3) model simplification, which must be done in order to simplify the matrix of polygonal surfaces, and reduce models' megabytes, and (4) create the augmented reality project. Once these procedures are performed, the augmented reality project can be saved and visualized in mobile devices. The volumetric model from a computed tomography acquisition is available in any mobile device screen, superimposed on a marker. This approach facilitates the visualization of the model, giving the precise location of structures and abnormalities, as supernumerary teeth, bone fractures and asymmetries. Also, the model is saved for future and multiple visualization. Augmented reality application is a new perspective in dentistry although it is in an early phase. It can be created by integrating multiple technologies and has a great potential to support learning and teaching, and improve how 3D models from medical images are seen (AU).


O objetivo desse trabalho é introduzir uma ferramenta de visualização e interação baseada em realidade aumentada (RA) em dispositivos móveis utilizando imagens volumétricas em três dimensões (3D) a partir de aquisições tomográficas reais de pacientes, e descrever os passos para o preparo dos modelos para tais visualizações tridimensionais. A RA foi construída correlacionando imagens tomográficas e programas de computador livres, na seguinte sequência: (1) imagem adquirida, que consiste em imagens mutiplanares que podem ser visualizadas como renderizações 3D e são a base para a construção de superfícies poligonais de estruturas anatômicas específicas de interesse, (2) criação dos modelos volumétricos, passo no qual o modelo 3D pode ser salvo e exportado como uma malha poligonal 3D em formato de arquivo .stl, (3)simplificação do modelo, que deve ser executada com a finalidade de simplificar a matriz de superfícies poligonais e consequentemente reduzir os megabytes do modelo, e (4) criação do projeto de realidade aumentada. Essa abordagem facilita a visualização do modelo tomográfico, dando a localização precisa de estruturas e anormalidades, como dentes supranumerários, fraturas ósseas e assimetrias. Além disso, o referido modelo pode ser salvo para múltiplias visualizações futuras. A aplicação da realidade aumentada é uma nova perspectiva em Odontologia apesar de estar em fase inicial. Pode ser criada integrando múltiplas tecnologias e apresenta grande potencial para auxiliar o ensino e a aprendizagem, e para melhorar a forma como modelos 3D originados de imagens médicas são visualizados (AU).


Assuntos
Tomógrafos Computadorizados , Radiografia Dentária Digital/instrumentação , Imageamento Tridimensional/instrumentação , Realidade Aumentada , Computadores de Mão
7.
Ciênc. rural ; 43(4): 736-742, abr. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-669377

RESUMO

Objetivou-se avaliar a morfologia de potros da raça Brasileiro de Hipismo, utilizando análise de imagens digitais e medidas de perímetros corporais para estimativa de índices corporais dos animais. As mensurações lineares e angulares foram obtidas utilizando imagens digitais dos potros com câmera acionada pelo aplicativo Simi Reality Motion Systems®. As medidas foram baseadas em pontos anatômicos realçados com 19 marcadores reflexivos. A análise estatística descritiva dos resultados foi realizada utilizando o programa SAS. Os potros estavam em crescimento, com aumento das medidas lineares de altura na cernelha e na garupa, comprimento do corpo, distância escápulo-metacarpofalângica e nos comprimentos do pescoço, da perna e do antebraço. Os ângulos úmero-radial, metacarpo-falângico, fêmoro-tibial, tíbio-metatarsico aumentaram com a idade, enquanto que os ângulos da cabeça, do pescoço, coxo-femoral, metatarso-falângico, escápulo-solo e coxo-solo foram variáveis entre os momentos de avaliação. Os potros foram classificados em mediolíneos e hipermétricos pelos índices Corporal e Dáctilo-torácico, respectivamente. A avaliação do crescimento dos potros foi possível através da imagem digital.


This research aimed to evaluate the morphology of Brasileiro de Hipismo foals using digital image analysis and girth measurements to estimate body indexes of animals. The linear and angular measurements were obtained by digital images of the foals with camera triggered by Simi Reality Motion Systems®. The measures were based on anatomical landmarks highlighted with 19 reflective markers. A descriptive statistical analysis of the results was performed using the SAS program. The foals were growing, with increased linear measurements of height at withers and croup, body length, distance from shoulder-fetlock and neck length, leg length and forearm length. The angles humerus-radial, metacarpal-falangeano, femoro-tibial, tibio-metatarsal increased with age, whiles the angles of the head, neck, coxofemoral, metatarsal-falangeano, shoulder-floor and coxae-floor were variable among the periods. The foals were classified as medium shape and hypermetric by Corporal Index, Dactilo-thoracic Index, respectively. Assessment of growth of the foals was possible through a digital image.

8.
Ciênc. rural ; 42(9): 1568-1574, set. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-648464

RESUMO

A reflectância da folha em determinados comprimentos de onda pode ser uma alternativa para estimar a concentração de nitrogênio (N) na planta, devido à relação entre o teor de clorofila e de N no tecido foliar. Este trabalho teve por objetivo avaliar índices da cor verde em grama-bermuda para predizer o nível de N na planta. O experimento foi conduzido em área comercial de produção de grama-bermuda, localizada na cidade de Capela do Alto/SP. O delineamento experimental utilizado foi de blocos ao acaso, com cinco tratamentos (0, 150, 300, 450 e 600kg de N ha-1) e quatro repetições. Foi avaliada a reflectância das folhas pelo uso de medidor de cor de grama, clorofilômetro, e por meio de análise da imagem digital. O matiz (H) e índice de cor verde escuro (ICVE), calculados com base nos índices de reflectância da imagem digital, o ICVE, obtido com medidor de cor de grama, e a intensidade de coloração verde (ICV), obtida com o clorofilômetro, apresentaram forte correlação positiva com a concentração de N e a taxa de cobertura do solo (TCS) da grama-bermuda, podendo ser utilizados como índices auxiliares na recomendação de adubação nitrogenada para a cultura. Os valores obtidos que podem servir como primeiros índices para avaliação do estado nutricional em N na grama-bermuda Celebration são: H de 88 a 109o e ICVE de 0,54 a 0,66 (imagem digital); H de 67 a 76o e ICVE de 0,41 a 0,44 (medidor de cor da grama TCM 500); e ICV de 374 a 471 (clorofilômetro CM 1000).


Leaves reflectance in a certain wavelength can be an alternative to estimate the N concentration in the plant because of the relationship between the chlorophyll content and N in the leaf tissue. This research aimed to evaluate the index of green color of Bermuda grass to predict the nutritional status in N. The experiment was installed and conducted in an area of grass commercial production, located in "Capela do Alto / SP". The experimental design was randomized blocks, with five treatments: 0, 150, 300, 450 and 600kg ha-1 and four replications. It was evaluated the leaves reflectance by using the grass color meter, chlorophyll meter and by the digital image analysis. The hue (H) and dark green color index (DGCI), calculated based on rates of reflectance of the digital image, the DGCI, obtained by grass color meter and intensity of green color obtained with chlorophyll meter presented strong positive correlation with N concentration and the soil cover rate of Bermuda grass which can be used as auxiliary index to assist in the recommendation of nitrogen fertilization. The values that can serve as the primary index for assessing the nutritional status of N in Celebration Bermuda grass are: H 88 to 109o and DGCI 0.54 to 0,66 (digital image); H 67 to 76o and DGCI 0.41 to 0.44 (TCM 500 color grass meter) and GCI 374 to 471 (CM 1000 chlorophyll metter).

9.
ImplantNews ; 9(6): 803-809, 2012. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-850980

RESUMO

Os micromovimentos excessivos entre implante e osso peri-implantar são uma das primeiras causas para a não osseointegração. Todavia, não existe nenhum método clínico disponível para medir diretamente os micromovimentos. A análise da frequência de ressonância (AFR), método muito utilizado, quantifica indiretamente a estabilidade implantar sem, contudo, medir deslocamentos. A correlação de imagem digital tridimensional (CID 3D), técnica óptica de medição sem contato, segue o campo de micromovimentos da superfície de um objeto. O objetivo principal deste trabalho foi validar o método CID 3D correlacionando-o com a AFR. Secundariamente, pretendeu perceber se a alteração dos pilares protéticos de standard (SD) para platform-switching (PS) influencia os micromovimentos dos implantes. A metodologia utilizada consistiu em um modelo experimental ex vivo com mandíbulas de porco frescas isoladas, onde foram colocados 30 implantes endósseos e pilares de cicatrização (SD e PS, n = 15 para cada grupo). Sobre estes se exerceu uma carga compressiva vertical de 100 N. A medição dos micromovimentos efetuou-se pelo programa Vic-3D 2010 (CorrelatedSolutions, Columbia, EUA). Os resultados obtidos foram comparados com os valores de ISQ (Implant Stability Quotient) do sistema de AFR (Osstell, IntegrationDiagnostic, Suécia) obtidos previamente. Pelos resultados, verificou-se uma correlação entre a mobilidade medida por CID 3D e os valores de ISQ, mas apenas na direção mesiodistal (U). Dentro das limitações deste estudo, o método de CID 3D parece ser capaz de medir os micromovimentos de implantes dentários. Os resultados parecem estar correlacionados com os valores de AFR. Os implantes com pilares PS apresentaram, em média, valores de micromovimentos mais baixos.


One of the first causes for not occurring osseointegration is the excessive micromovements between the implant and perimplant bone. However, there is no clinical method available to directly measure micromovements. Resonance Frequency Analysis (RFA), a largely used method, quantifies implant stability indirectly without measuring displacements. The 3D Digital Image Correlation method (3D DIC) is a non-contact optical measurement technique that tracks the surface displacement field of an object. The primary objective of this work is to validate 3D DIC with the RFA method. Secondarily, we pretend to understand if the change of prosthetic abutments from standard (SD) to platform-switching (PS) influences dental implant micromovements. The methodology used consisted in an experimental ex vivo model with isolated fresh porcine mandibles where 30 endosseous implants were placed with healing abutments (SD and PS, n=15 for each group). These were submitted to a vertical compressive load of 100N. Micromovement measurements were determined by Vic-3D 2010 (CorrelatedSolutions, Columbia, EUA). Results were compared with RFA (Osstell, IntegrationDiagnostic, Sweden) ISQ values (Implant Stability Quotient) obtained previously. The results show correlation between implant mobility measured by 3D DIC and ISQ values, but only in mesiodistal direction (U). Within the limitations of this study, 3D DIC method seems to be capable to measure dental implant micromovements. The results suggest a correlation with the ISQ values obtained by RFA. Although not statiscally significant, implants with PS abutments presented lower micromovement values.


Assuntos
Animais , Implantes Dentários , Processamento de Imagem Assistida por Computador , Osseointegração
10.
Camaragibe; s.n; dez. 2010. 106 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-605438

RESUMO

Wste trabalho teve por objetivos avaliar a radiopacidade de cimentos resinosos e pinos de fibra de vidro no filme e sistemas digitais, e a influência destes materiais quando inseridos no canal radicular...


The aim of this study was to evaluate the radiopacity of the resinous cements and glass fiber dowels on film and digital systems and evaluate the influence of these materials when inserted into the root canal...


Assuntos
Pinos Dentários , Intensificação de Imagem Radiográfica , Radiografia Dentária , Cimentos de Resina
11.
Psicol. estud ; 15(2): 401-408, abr.-jun. 2010.
Artigo em Português | Index Psicologia - Periódicos | ID: psi-50639

RESUMO

O artigo "A imagem digital como dispositivo de apropriação dos modos de subjetivação contemporâneos" trata de problematizar a imagem digital como emblema dos atuais modos de produção de subjetividade. Na imagem digital, o tempo é resignificado na despotencialização de seus aspectos acumulativos vindo a ser integrado a uma temporalidade transitória e de confluência de encontros. A discussão proposta expõe dimensões do conceito de virtual afirmando-o como potência imaginativa, fruto de agenciamentos múltiplos e heterogêneos entre arte, tecnologia e ciência fundando novas interações entre sujeito e mundo. É justamente, desde uma leitura da realidade como pura transformação, não existindo essências e sim estados de coisas, que a simulação se torna adequada para pensar as relações entre imagem digital e subjetividade.(AU)


The article "The digital image as a tool for the assumption of contemporary subjectivizing methods" brings into the matter the digital image as the symbol of the current ways we produce subjectivity. In the digital image, time is redefined in the weakness of its accumulative aspects eventually integrated to a momentary temporality and of confluence of meetings. The proposed discussion exposes dimensions of the concept of virtuality strengthning it as an imaginative power, creation of multiple and heterogeneous administrations among art, technology and science establishing new interactions between man and world. Since reality is seen as pure transformation, without the existence of essences and yet the state of things, simulation becomes appropriate to the thinking of the relationship between digital image and subjectivity.(AU)


El artículo "La imagen digital como dispositivo de apropiación de los modos de subjetividad contemporáneos" trata de problematizar la imagen digital como emblema de los actuales modo de producción de subjetividad. En la imagen digital, el tiempo es otra vez significado en la pérdida de potencia de sus aspectos acumulativos siendo integrado a una temporalidad transitoria y de confluencia de encuentros. La discusión propuesta expone dimensiones del concepto de virtual afirmándolo como potencia imaginativa, fruto de agenciamentos múltiplos y heterogéneos entre arte, tecnología y ciencia fundando nuevas interacciones entre sujeto y mundo. Es justamente, desde una lectura de la realidad como pura transformación, no existiendo esencias y sí estados de cosas que la simulación se torna adecuada para pensar las relaciones entre imagen digital y subjetividad.(AU)


Assuntos
Psicologia
12.
Psicol. estud ; 15(2): 401-408, abr.-jun. 2010.
Artigo em Português | LILACS | ID: lil-558880

RESUMO

O artigo "A imagem digital como dispositivo de apropriação dos modos de subjetivação contemporâneos" trata de problematizar a imagem digital como emblema dos atuais modos de produção de subjetividade. Na imagem digital, o tempo é resignificado na despotencialização de seus aspectos acumulativos vindo a ser integrado a uma temporalidade transitória e de confluência de encontros. A discussão proposta expõe dimensões do conceito de virtual afirmando-o como potência imaginativa, fruto de agenciamentos múltiplos e heterogêneos entre arte, tecnologia e ciência fundando novas interações entre sujeito e mundo. É justamente, desde uma leitura da realidade como pura transformação, não existindo essências e sim estados de coisas, que a simulação se torna adequada para pensar as relações entre imagem digital e subjetividade.


The article "The digital image as a tool for the assumption of contemporary subjectivizing methods" brings into the matter the digital image as the symbol of the current ways we produce subjectivity. In the digital image, time is redefined in the weakness of its accumulative aspects eventually integrated to a momentary temporality and of confluence of meetings. The proposed discussion exposes dimensions of the concept of virtuality strengthning it as an imaginative power, creation of multiple and heterogeneous administrations among art, technology and science establishing new interactions between man and world. Since reality is seen as pure transformation, without the existence of essences and yet the state of things, simulation becomes appropriate to the thinking of the relationship between digital image and subjectivity.


El artículo "La imagen digital como dispositivo de apropiación de los modos de subjetividad contemporáneos" trata de problematizar la imagen digital como emblema de los actuales modo de producción de subjetividad. En la imagen digital, el tiempo es otra vez significado en la pérdida de potencia de sus aspectos acumulativos siendo integrado a una temporalidad transitoria y de confluencia de encuentros. La discusión propuesta expone dimensiones del concepto de virtual afirmándolo como potencia imaginativa, fruto de agenciamentos múltiplos y heterogéneos entre arte, tecnología y ciencia fundando nuevas interacciones entre sujeto y mundo. Es justamente, desde una lectura de la realidad como pura transformación, no existiendo esencias y sí estados de cosas que la simulación se torna adecuada para pensar las relaciones entre imagen digital y subjetividad.


Assuntos
Psicologia
13.
Rev. dental press estét ; 7(1): 54-71, jan.-mar. 2010. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-557465

RESUMO

A comparação visual com escalas de cor, universalmente empregada para avaliar o resultado das diferentes substâncias, técnicas e aparelhos utilizados no clareamento dental, tem se mostrado um método limitado, questionável, subjetivo e confiável. Os métodos instrumentais, que utilizam espectroscópios ou imagens digitais, têm se mostrado mais adequados por oferecerem avaliações objetivas, maior reprodutibilidade e confiabilidade. Neste artigo, serão apresentados e discutidos os resultados obtidos com a utilização do ScanWhite© - softwre para avaliação objetiva do nível de clareamento dental e apoio à decisão clínica, que baseia sua avaliação no processamento computacional de imagens digitais. Esse tem como principais diferenciais: (1) algaritmo calibrador para compensar as variações de luminosidade do ambiente, (2) apresentação dos resultados em valores numéricos e através do gráfico de evolução do clareamento dental, (3) interface intuitiva e facilidade de uso, (4) determinação dos índices de apoio à decisão (IPS - índice de possibilidade de sucesso, e IRS - índice de risco de sensibilidade antes do início do tratamento) e (5) emissão de relatório geral, autorizações e recomendações pós-clareamento.


Assuntos
Humanos , Feminino , Adulto , Clareamento Dental/métodos , Fotografia Dentária , Software , Cor , Sensibilidade da Dentina , Estética Dentária , Satisfação do Paciente , Sorriso
14.
Radiol. bras ; 42(2): 115-120, mar.-abr. 2009. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-513153

RESUMO

OBJETIVO: Avaliar o impacto sobre o treinamento de residentes utilizando uma ferramenta computacional dedicada à avaliação do desempenho da leitura de imagens radiológicas convencionais e digitais. MATERIAIS E MÉTODOS: O treinamento foi realizado no Laboratório de Qualificação de Imagens Médicas (QualIM). Os residentes de radiologia efetuaram cerca de 1.000 leituras de um total de 60 imagens obtidas de um simulador estatístico (Alvim®) que apresenta fibras e microcalcificações de dimensões variadas. O desempenhodos residentes na detecção dessas estruturas foi avaliado por meio de parâmetros estatísticos. RESULTADOS:Os resultados da probabilidade de detectabilidade foram de 0,789 e 0,818 para os sistemas convencional e digital, respectivamente. As taxas de falso-positivos foram de 8% e 6% e os valores de verdadeiro- -positivos, de 66% e 70%, respectivamente. O valor de kappa total foi 0,553 para as leituras em negatoscópio e 0,615 em monitor. A área sob a curva ROC foi de 0,716 para leitura em filme e 0,810 para monitor.CONCLUSÃO: O treinamento proposto mostrou ser efetivo e apresentou impacto positivo sobre o desempenhodos residentes, constituindo-se em interessante ferramenta pedagógica. Os resultados sugerem que o método de treinamento baseado na leitura de simuladores pode produzir um melhor desempenho dos profissionais na interpretação das imagens mamográficas.


OBJECTIVE: The present study was aimed at evaluating the performance of residents trained in the reading of conventional and digital mammography images with a specific computational tool. MATERIALS AND METHODS: The training was accomplished in the Laboratory of Medical Images Qualification (QualIM û Laboratório de Qualificação de Imagens Médicas). Residents in radiology performed approximately 1,000 readings of a set of 60 images acquired from a statistical phantom (Alvim®) presenting microcalcifications and fibers with different sizes. The analysis of the residents' performance in the detection of these structures was based on statistical parameters. RESULTS: Values for detection probability were respectively 0.789 and 0.818 for conventional and digital systems. False-positive rates were 8% and 6%, and true-positive rates, 66% and 70% respectively. The total kappa value was 0.553 for readings on the negatoscope (hard-copy readings), and 0.615 on the monitor (soft-copy readings). The area under the ROC curve was 0.716 forhard-copy readings and 0.810 for soft-copy readings. CONCLUSION: The training has showed to be effective,with a positive impact on the residents' performance, representing an interesting educational tool. The resultsof the present study suggest that this method of training based on the reading of images from phantoms can improve the practitioners' performance in the interpretation of mammographic images.


Assuntos
Humanos , Instrução por Computador , Diagnóstico por Computador/métodos , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Materiais de Ensino , Radiografia/métodos
15.
Rev. bras. odontol ; 65(1): 42-47, jan.-jun. 2008. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-541697

RESUMO

O desenvolvimento de novos sistemas de informática contribuiu sobremaneira para avanços em diversos setores da sociedade e também na Odontologia, principalmente na área da Radiologia. A reduzida exposição à radiação ionizante é uma das grandes vantagens do uso da radiologia digital, assim como uma maior facilidade de armazenamento das imagens e, consequentemente, intensificação da troca de informações entre os grandes centros e profissinais da saúde. O presente trabalho visa apresentar esta nova tecnologia, discutir suas vantangens e desvantagens, assim como fazer uma breve revisão da literatura.


Assuntos
Radiografia Dentária Digital/normas , Radiografia Dentária Digital/tendências , Literatura de Revisão como Assunto
16.
Rev. Fac. Odontol. Porto Alegre ; 48(1/3): 17-21, 2007.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-533977

RESUMO

A radiopacidade é uma das propriedades físicas requeridas pelos diferentes materiais de uso endodôntico, permitindo avaliar o preenchimentodo sistema de canais radiculares. O objetivo deste estudo foi avaliar a densidade óptica de três pastas de hidróxido de cálcio – hidróxido de cálcio pró-análise (Biodinâmica) + propilenoglicol 400 (Farmácia Extrato Puro), pasta Calen (SS White) e pasta UltraCal XS (UltraDent), associadas a um simulador de tecidos. Foram confeccionados 15 corpos-de-prova a partir de um tubo de polietileno, que originou três grupos experimentais, com cinco tubos preenchidos com cada uma das pastas avaliadas. Com o intuito de averiguar a interferência do tubo utilizado na radiopacidade, foram incluídos como amostras, mais dois grupos; um composto apenas com o dente e outro com um tubo vazio inserido no interior do canal radicular. Foram obtidas 25 imagens digitais padronizadas, utilizando o sistema Visualix, sendo 5 para cada grupo. As imagens foram exportadas para o programa Adobe Photoshop v. 7.0, no qual foi determinada a média e o desvio padrão da densidade óptica em uma área padronizada da imagem, correspondente à posição do tubo. Os valores médios de densidade óptica encontrados foram, em ordem decrescente, pasta UltraCal XS (236,25 ± 2,96), pasta Calen (230,32 ± 3,49) e pasta Pró-análise + Propilenoglicol (210,95 ± 3,29). O sistema Visualix foi capaz de identificar diferentes padrões de radiopacidade para os materiais testados, sendo que todas as pastas apresentaram radiopacidade significativamente maior que a do conduto radicular vazio e diferiram significativamente entre si.


Radiopacity is one of the physical properties requested by the different materials of endodontic use, which evaluate the filling of the pulp canal system. The aim of this study was to evaluate the radiopacity of three calcium hydroxide pastes: calcium hydroxide pro-analysis (biodynamics) + Propilenoglicol 400 (pharmacy pure extract), Calen (SS white) and UltraCal XS (Ultra Dent), associated to a tissue simulator. Fifteen samples were manufactured using a polyethylene tube, originating three experimental groups, with five tubes filled with each one of the pastes evaluated. In order to find out the interference of the tube in the radiopacity, another two groups were included: one composed just by the tooth and other with an empty tube inserted in the root canal. Using the Visuallix system, 25 standardized digital images were obtained (5 of each group). The images were exported to Adobe Photoshop v. 7.0 software, in order to obtain the mean values and standard deviation of gray levels in a standardized area of the image, corresponding to the tube position. The mean values of optic density were, in decreasing order, UltraCal XS (236,25 +2,96), Calen (230,32 + 3,49) and pro-analysis+ propilenoglicol (210,95 + 3,29). The Visualix system was able to identify different patterns of the radiopacity in the tested materials, which were more radiopaque than the empty root canal and significantly different in terms of radiopacity.


Assuntos
Hidróxido de Cálcio/química , Radiografia Dentária Digital , Materiais Restauradores do Canal Radicular
17.
Rev. bras. odontol ; 63(3/4): 152-157, 2006. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-541662

RESUMO

O objetivo deste estudo foi avaliar dois sistemas de imagens no diagnóstico de lesão de furca. Foram realizados defeitos ósseos artificiais em suínos utilizando brocas esféricas para a obtenção de radiografias intra-orais. Periodontistas e radiologistas analisaram esta simulações por meio de filmes convencionais e imagens digitalizadas. Foi observado que os periodontistas apresentaram dificuldades em diagnosticar lesões de furca menores nos molares superiores e inferiores, enquanto que os radiologistas somente nos superiores. Quanto aos sistemas de avaliação, apresentaram resultados semelhantes, concluindo-se que a imagem digitalizada não aumenta a acurácia mas também não diminuiu a qualidade, importante para arquivamento e transferência de dados.


Assuntos
Animais , Defeitos da Furca/diagnóstico , Diagnóstico por Imagem/normas , Radiografia Dentária Digital/normas , Radiografia Interproximal/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...